1300 W per module
- Rated high-line class, per module
- 1,300 W
- Reference efficiency class*
- Platinum
- Reference maximum +12 V current at 110 V AC*
- 83 A
- Reference maximum +12 V current at 230 V AC*
- 108 A

Modular power for rackable AI systems.
High-output CRPS modules for compatible GPU server nodes, rack-installed workstations and specialist AI hardware. Cloud 9 supplies power components for complete systems, platform upgrades and independent requirements, with available capacity, module compatibility, management and cooling considered within the host architecture.
A rackable AI system brings GPUs, host processors, memory, storage, networking and cooling into a compact enclosure. Its electrical design has to accommodate sustained demand, changes in load and the operating limits of the installation. CRPS modules provide a serviceable power format for systems equipped with the appropriate module bays and power-distribution hardware.
The modules deliver regulated power through a compatible system interface. The host then distributes and converts that power where the CPU, GPUs and supporting electronics need it. Module rating, input supply, current sharing and cooling are all part of the same calculation. CRPS capacity is not a substitute for the actual system power budget.
Cloud 9’s CRPS range supports power infrastructure for GPU servers and selected workstation-node designs, including replacement and platform integration requirements. Selection follows the host, not the wattage label alone.

A CRPS module condenses AC-to-DC conversion, supervision and cooling into a narrow, removable assembly. Its functions are closely integrated, not a stack of independent boards. The exploded view separates major structures to make the power path easier to follow.

The enclosed module uses a compact fan, internal flow path and mechanical handling features designed around its supported power and thermal operating range.
The incoming supply passes through input protection and electromagnetic-interference filtering, limiting unwanted disturbances entering or leaving the module.
Power-factor correction shapes AC input current and establishes the internal DC bus for the main conversion stage. Energy storage supports the defined operating response.
Switching circuitry, magnetic components and an isolation barrier transfer power to the output side. Exact topology and component placement depend on the design.
Output circuitry rectifies, filters and supervises the main 12 V supply, responding to load changes and defined faults. Local CPU and GPU voltages are produced downstream in the host.
A host-compatible card-edge interface carries DC power and control signals. Supported implementations provide current-sharing, status and PMBus communication through the host design.
The range covers six high-output CRPS classes. Each figure describes an individual module, not the power available after a module failure in a redundant assembly. Usable output also depends on AC input and the host’s distribution and cooling system.

Scroll the comparison horizontally to view all six classes.
| Characteristic | 1300 W | 1600 W | 2000 W | 2400 W | 2700 W | 3200 W |
|---|---|---|---|---|---|---|
| Rated high-line class, per module | 1,300 W | 1,600 W | 2,000 W | 2,400 W | 2,700 W | 3,200 W |
| Reference efficiency class* | Platinum | Platinum | Platinum | Platinum | Titanium | Titanium |
| Reference maximum +12 V current at 110 V AC* | 83 A | 83 A | 83 A | 98 A | 110.7 A | 119 A |
| Reference maximum +12 V current at 230 V AC* | 108 A | 132 A | 164 A | 195 A | 221.6 A | 262 A |
Family architecture: CRPS-185 reference form factor / 12 V main output / Host-dependent PMBus and current-sharing / Forced air / Compatible N+1 and hot-swap designs.
*Power and efficiency figures refer to the stated engineering reference platforms. Available +12 V output depends on AC input conditions. Select the module and host together for supported ratings, certification, current sharing, protection and service operation.

A redundant system must have enough working module capacity to support the required load after a designated module becomes unavailable. N+1 describes a supported architecture, not a property created merely by installing an extra supply. Current sharing, the power backplane and input conditions determine whether the design meets its operating requirement.
N+1 planning / Capacity after failure / Supported sharing

In an appropriately designed system, a failed module can be replaced while the remaining units continue supporting the load. Hot-swap capability depends on the host, the correct module and safe service procedures; it does not make an unsupported enclosure hot-swappable.
Serviceable modules / Host interlock and backplane / Compatible replacement

A managed supply can report operating and fault information through a supported control interface. PMBus can help the host track module status and identify electrical or thermal events. Available measurements and management functions depend on the selected power supply and the platform software.
PMBus / Status and fault reporting / Power supervision

In a compact rackable node, conversion losses become heat that must be removed. High-efficiency power conversion reduces this load, while the module’s forced-air design, inlet conditions and clearance determine whether it can support its rated output in the installed environment.
Platinum and Titanium reference classes / Conversion losses / Forced airflow

High-power GPUs rely on the host’s power distribution, power budget, regulation and cooling. CRPS selection therefore includes electrical input, module capacity, power path, processor and GPU demand, redundancy policy and the actual chassis environment rather than GPU count alone.
Host distribution / Input derating / GPU and CPU power budget
CRPS modules support the power architecture of compatible AI server nodes and rack-installed systems. For cable-connected workstation designs, the Power Supplies overview also explains the separate ATX format.