Unbranded slim CRPS modules and compatible server power bay, one module partially withdrawn.

CRPS Power Supplies

Modular power for rackable AI systems.

High-output CRPS modules for compatible GPU server nodes, rack-installed workstations and specialist AI hardware. Cloud 9 supplies power components for complete systems, platform upgrades and independent requirements, with available capacity, module compatibility, management and cooling considered within the host architecture.

Power within the node

Power delivery designed around the host.

A rackable AI system brings GPUs, host processors, memory, storage, networking and cooling into a compact enclosure. Its electrical design has to accommodate sustained demand, changes in load and the operating limits of the installation. CRPS modules provide a serviceable power format for systems equipped with the appropriate module bays and power-distribution hardware.

The modules deliver regulated power through a compatible system interface. The host then distributes and converts that power where the CPU, GPUs and supporting electronics need it. Module rating, input supply, current sharing and cooling are all part of the same calculation. CRPS capacity is not a substitute for the actual system power budget.

Cloud 9’s CRPS range supports power infrastructure for GPU servers and selected workstation-node designs, including replacement and platform integration requirements. Selection follows the host, not the wattage label alone.

Rackable AI node cutaway showing its CRPS module bay, host power distribution, processor, accelerator area and forced-air path.
Power architecture for a single server node.
Inside the module

Inside a high-density CRPS power supply.

A CRPS module condenses AC-to-DC conversion, supervision and cooling into a narrow, removable assembly. Its functions are closely integrated, not a stack of independent boards. The exploded view separates major structures to make the power path easier to follow.

Representative exploded slim CRPS module showing enclosure, compact fan, one integrated circuit assembly and blind-mate edge connector.
Power supplies can retain hazardous energy after disconnection.
  1. 01

    Service enclosure and forced-air cooling

    The enclosed module uses a compact fan, internal flow path and mechanical handling features designed around its supported power and thermal operating range.

  2. 02

    Input filtering and electrical protection

    The incoming supply passes through input protection and electromagnetic-interference filtering, limiting unwanted disturbances entering or leaving the module.

  3. 03

    Power-factor correction and DC energy storage

    Power-factor correction shapes AC input current and establishes the internal DC bus for the main conversion stage. Energy storage supports the defined operating response.

  4. 04

    High-frequency conversion and isolation

    Switching circuitry, magnetic components and an isolation barrier transfer power to the output side. Exact topology and component placement depend on the design.

  5. 05

    Regulated 12 V output

    Output circuitry rectifies, filters and supervises the main 12 V supply, responding to load changes and defined faults. Local CPU and GPU voltages are produced downstream in the host.

  6. 06

    Blind-mate interface and management

    A host-compatible card-edge interface carries DC power and control signals. Supported implementations provide current-sharing, status and PMBus communication through the host design.

CRPS range

Six module classes for supported power architectures.

The range covers six high-output CRPS classes. Each figure describes an individual module, not the power available after a module failure in a redundant assembly. Usable output also depends on AC input and the host’s distribution and cooling system.

Three matching unbranded narrow CRPS modules shown together, including service and card-edge ends.
CRPS module dimensions and interchangeability follow the selected family and host.

Scroll the comparison horizontally to view all six classes.

Per-module CRPS engineering reference classes
Characteristic1300 W1600 W2000 W2400 W2700 W3200 W
Rated high-line class, per module1,300 W1,600 W2,000 W2,400 W2,700 W3,200 W
Reference efficiency class*PlatinumPlatinumPlatinumPlatinumTitaniumTitanium
Reference maximum +12 V current at 110 V AC*83 A83 A83 A98 A110.7 A119 A
Reference maximum +12 V current at 230 V AC*108 A132 A164 A195 A221.6 A262 A

1300 W per module

Rated high-line class, per module
1,300 W
Reference efficiency class*
Platinum
Reference maximum +12 V current at 110 V AC*
83 A
Reference maximum +12 V current at 230 V AC*
108 A

1600 W per module

Rated high-line class, per module
1,600 W
Reference efficiency class*
Platinum
Reference maximum +12 V current at 110 V AC*
83 A
Reference maximum +12 V current at 230 V AC*
132 A

2000 W per module

Rated high-line class, per module
2,000 W
Reference efficiency class*
Platinum
Reference maximum +12 V current at 110 V AC*
83 A
Reference maximum +12 V current at 230 V AC*
164 A

2400 W per module

Rated high-line class, per module
2,400 W
Reference efficiency class*
Platinum
Reference maximum +12 V current at 110 V AC*
98 A
Reference maximum +12 V current at 230 V AC*
195 A

2700 W per module

Rated high-line class, per module
2,700 W
Reference efficiency class*
Titanium
Reference maximum +12 V current at 110 V AC*
110.7 A
Reference maximum +12 V current at 230 V AC*
221.6 A

3200 W per module

Rated high-line class, per module
3,200 W
Reference efficiency class*
Titanium
Reference maximum +12 V current at 110 V AC*
119 A
Reference maximum +12 V current at 230 V AC*
262 A

Family architecture: CRPS-185 reference form factor / 12 V main output / Host-dependent PMBus and current-sharing / Forced air / Compatible N+1 and hot-swap designs.

*Power and efficiency figures refer to the stated engineering reference platforms. Available +12 V output depends on AC input conditions. Select the module and host together for supported ratings, certification, current sharing, protection and service operation.

The engineering that counts

Designed for modular power at compute scale.

Three matching CRPS modules in a compatible power bay, illustrating an N+1 arrangement without asserting guaranteed capacity.
Three-module power bay. Available capacity after a module loss depends on the host and input conditions.
Engineering

Capacity that survives a module failure

A redundant system must have enough working module capacity to support the required load after a designated module becomes unavailable. N+1 describes a supported architecture, not a property created merely by installing an extra supply. Current sharing, the power backplane and input conditions determine whether the design meets its operating requirement.

N+1 planning / Capacity after failure / Supported sharing

One narrow CRPS power module partially withdrawn from a compatible server bay, showing its service handle and mating position.
Hot-swap servicing requires a compatible power module and host.
Engineering

Service access without a full shutdown

In an appropriately designed system, a failed module can be replaced while the remaining units continue supporting the load. Hot-swap capability depends on the host, the correct module and safe service procedures; it does not make an unsupported enclosure hot-swappable.

Serviceable modules / Host interlock and backplane / Compatible replacement

Close technical view of a CRPS management circuit area and host control connection, with no fabricated telemetry readings.
Power-supply management features depend on the module and host platform.
Engineering

Power information available to the host

A managed supply can report operating and fault information through a supported control interface. PMBus can help the host track module status and identify electrical or thermal events. Available measurements and management functions depend on the selected power supply and the platform software.

PMBus / Status and fault reporting / Power supervision

Cutaway view of a slim CRPS power module with compact service-face fan and directed internal cooling path.
Engineering

Efficient conversion in constrained space

In a compact rackable node, conversion losses become heat that must be removed. High-efficiency power conversion reduces this load, while the module’s forced-air design, inlet conditions and clearance determine whether it can support its rated output in the installed environment.

Platinum and Titanium reference classes / Conversion losses / Forced airflow

Complete CRPS module exterior with a service handle, latch, fan grille and input connector.
CRPS module
Host distribution interface
  • Accelerator load
  • Processor and memory
Rackable node with host-specific power distribution.
Engineering

A complete power architecture for AI hardware

High-power GPUs rely on the host’s power distribution, power budget, regulation and cooling. CRPS selection therefore includes electrical input, module capacity, power path, processor and GPU demand, redundancy policy and the actual chassis environment rather than GPU count alone.

Host distribution / Input derating / GPU and CPU power budget

Specify power as part of the node.