Solid-state storage for AI workstations and servers.

NVMe and SATA SSDs for model libraries, working datasets, applications and production content. Cloud 9 sources and supplies commercial and enterprise-class storage for new systems, capacity expansion and demanding data workloads.

STORAGE IN THE AI SYSTEM

AI work needs fast access to more than the model.

Model files are only part of the storage requirement. Training datasets, source media, application environments, checkpoints and generated content all need space, and much of that data must be accessed repeatedly as the work develops.

SSDs provide responsive working storage for these tasks, alongside capacity for larger local libraries. The right configuration considers how data is read and written, how often it changes, and how the drive connects to the rest of the system.

Cloud 9 sources storage with that complete requirement in view, from a compact AI workstation to a multi-GPU server platform.

Storage performance can reduce time spent waiting for data. GPU compute and system memory remain separate resources.

Illustrative working files arranged around solid-state storage.
Model library · Working dataset · Checkpoints · Production content

EXPLORE THE RANGE

Choose storage around the platform and the work.

NVMe and SATA offer different connection paths. Commercial and enterprise classes address different operating requirements within those families.

NVMe SSDs

High-throughput storage for active AI workloads.

NVMe SSDs use PCIe connectivity to support demanding data transfers and concurrent storage access. Explore options for model loading, dataset preparation, checkpoint handling and production workloads where storage throughput and responsiveness matter.

Select the form factor, capacity, endurance and thermal requirements around the host platform and the way the drive will be used.

Commercial and enterprise classes · Working storage and capacity options

Illustrative M.2 NVMe solid-state drive.

SATA SSDs

Solid-state capacity for SATA-equipped systems.

SATA SSDs bring flash storage to systems with compatible SATA connections and drive bays. They provide a route for application storage, content libraries, system upgrades and workloads whose access requirements fit the interface.

Commercial and enterprise options address different operating demands, with endurance, consistency and protection features checked against the selected drive.

Commercial and enterprise classes · Compatible SATA platforms

Illustrative 2.5-inch SATA solid-state drive.

Commercial Class

Storage for application, development and production requirements within the selected drive’s specification. Professional use does not imply enterprise endurance or protection.

Enterprise Class

Storage selected for defined server and sustained-workload requirements. Check endurance, consistent response, power-loss behaviour and management features against the specific drive.

EXPLORE THE ANATOMY

Inside an SSD: how the hardware handles your data.

Choose an illustrative design, then select a component to see its role in storing, moving and protecting data. The examples explain architecture, not a catalogue of available products.

Illustrative M.2 2280 NVMe design with separate controller, NAND and DRAM regions.

NVMe · Illustrative design

M.2 2280 / Onboard-DRAM example

22 × 80 mm

A common physical format with a separate DRAM package in this illustrative design. Identify the persistent storage, controller and volatile memory separately.

Other 2280 designs may omit DRAM or include different protection and thermal features.

NAND flash

Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages.

Plan room for the working library and the data produced by the task.

Read all six SSD design explanations and component roles

M.2 2242 / Compact-board example

A compact NVMe architecture illustrates how flash and its controller fit within a short board. Package arrangement varies between products.

Onboard DRAM and PLP are not depicted or promised. This example does not establish HMB support.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • PCIe / NVMe connection — The keyed edge connects this NVMe example to a compatible PCIe-capable host socket. M.2 shape alone does not establish protocol or electrical compatibility. Confirm slot support, supported length and host resources before selection.
  • Board and mounting — The board outline, key and fixing position determine physical fit. Length identifies the format, not a guaranteed capacity or performance level. Check clearance, supported length and component height against the host.

M.2 2280 / Onboard-DRAM example

A common physical format with a separate DRAM package in this illustrative design. Identify the persistent storage, controller and volatile memory separately.

Other 2280 designs may omit DRAM or include different protection and thermal features.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • Onboard DRAM — This example includes a separate volatile-memory package for drive-management functions. Its role is distinct from persistent NAND storage. DRAM presence is an architectural detail, not a stand-alone prediction of application speed.
  • PCIe / NVMe connection — The keyed edge connects this NVMe example to a compatible PCIe-capable host socket. M.2 shape alone does not establish protocol or electrical compatibility. Confirm slot support, supported length and host resources before selection.
  • Thermal path — Heat must pass from the working components into the supported thermal arrangement. Cooling depends on the drive and its installation. Sustained work needs appropriate operating conditions, not just a peak transfer figure.
  • Board and mounting — The board outline, key and fixing position determine physical fit. Length identifies the format, not a guaranteed capacity or performance level. Check clearance, supported length and component height against the host.

M.2 2280 / DRAM-less / HMB example

This example explains a supported DRAM-less NVMe approach. A separate functional inset shows HMB in host memory outside the SSD.

No onboard DRAM package is drawn. HMB is neither additional SSD capacity nor a substitute for backup power.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • Host Memory Buffer — In a supported DRAM-less NVMe design, HMB lets the drive use a portion of host memory. The memory is in the computer, not a chip on this SSD. Check both the drive design and host support. HMB is not power-loss protection.
  • PCIe / NVMe connection — The keyed edge connects this NVMe example to a compatible PCIe-capable host socket. M.2 shape alone does not establish protocol or electrical compatibility. Confirm slot support, supported length and host resources before selection.
  • Board and mounting — The board outline, key and fixing position determine physical fit. Length identifies the format, not a guaranteed capacity or performance level. Check clearance, supported length and component height against the host.

M.2 22110 / Protected-design example

The longer-board example shows how a drive can accommodate flash, control functions and hardware power-loss protection.

22110 is a dimension code. It does not mean every drive of this size has PLP, onboard DRAM or enterprise qualification.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • Onboard DRAM — This example includes a separate volatile-memory package for drive-management functions. Its role is distinct from persistent NAND storage. DRAM presence is an architectural detail, not a stand-alone prediction of application speed.
  • Hardware power-loss protection — The illustrated capacitors provide hold-up energy for defined drive operations after input power loss. Actual protection depends on the product. Match the documented protection to the write workload. Keep system power protection and backup separate.
  • PCIe / NVMe connection — The keyed edge connects this NVMe example to a compatible PCIe-capable host socket. M.2 shape alone does not establish protocol or electrical compatibility. Confirm slot support, supported length and host resources before selection.
  • Board and mounting — The board outline, key and fixing position determine physical fit. Length identifies the format, not a guaranteed capacity or performance level. Check clearance, supported length and component height against the host.

2.5-inch SATA / Standard-design example

A lifted cover reveals an intact SATA SSD board. The enclosure, NAND, controller and separate DRAM remain distinguishable.

This representative design does not imply every SATA SSD includes DRAM. Hardware PLP is not depicted.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • Onboard DRAM — This example includes a separate volatile-memory package for drive-management functions. Its role is distinct from persistent NAND storage. DRAM presence is an architectural detail, not a stand-alone prediction of application speed.
  • SATA data and power — Separate keyed data and power contacts connect this 2.5-inch SATA example to a compatible host arrangement. A similar-sized NVMe drive is not interchangeable simply because it fits in a bay.
  • Thermal path — Heat must pass from the working components into the supported thermal arrangement. Cooling depends on the drive and its installation. Sustained work needs appropriate operating conditions, not just a peak transfer figure.

2.5-inch SATA / Hardware-PLP example

A second SATA example shows the additional hold-up circuitry used in a hardware-protected design.

The change is the documented architecture, not a promise that all enterprise drives look alike or share one protection scope.

  • NAND flash — Non-volatile storage holds model files, datasets, applications and saved output. Capacity and endurance follow the selected drive, not the number of visible packages. Plan room for the working library and the data produced by the task.
  • SSD controller — The controller manages host requests and the use of flash, including mapping and internal data-management functions. The drive’s behaviour comes from the controller, firmware and flash working together.
  • Onboard DRAM — This example includes a separate volatile-memory package for drive-management functions. Its role is distinct from persistent NAND storage. DRAM presence is an architectural detail, not a stand-alone prediction of application speed.
  • Hardware power-loss protection — The illustrated capacitors provide hold-up energy for defined drive operations after input power loss. Actual protection depends on the product. Match the documented protection to the write workload. Keep system power protection and backup separate.
  • SATA data and power — Separate keyed data and power contacts connect this 2.5-inch SATA example to a compatible host arrangement. A similar-sized NVMe drive is not interchangeable simply because it fits in a bay.
  • Thermal path — Heat must pass from the working components into the supported thermal arrangement. Cooling depends on the drive and its installation. Sustained work needs appropriate operating conditions, not just a peak transfer figure.

M.2 board dimensions

  • M.2 224222 × 42 mm
  • M.2 228022 × 80 mm
  • M.2 2211022 × 110 mm

2242, 2280 and 22110 describe board dimensions, not a performance ranking. M.2 is a physical format and does not, by itself, mean NVMe.

SSD TECHNOLOGY

The technology behind responsive, high-capacity storage.

The useful differences are visible in how a drive handles the work: moving large files, retaining a substantial library, sustaining writes and operating within its thermal and power conditions.

Illustrative large-file transfer supported by solid-state storage.

Bandwidth for large transfers

A suitable interface and storage configuration can shorten the time spent moving model files, preparing datasets and handling checkpoints. The host connection, software and pattern of access determine how much of the available performance the application can use.

Working files
Model filesDataset preparationCheckpoint transfer
SSD working storage
Compatible host and application

Result depends on the host and workload.

Illustrative compact NAND storage hardware.

More work kept within reach

Modern NAND packs substantial storage into a small device. 3D NAND, TLC and QLC designs give drive makers different capacity and workload options. The useful choice considers the complete drive, including endurance and sustained behaviour, rather than treating one NAND label as a universal quality score.

3D NAND architecture.TLC and QLC are NAND design choices; usable capacity and workload fit depend on the complete drive. Conceptual cutaway, not a verified product cross-section.
Installed M.2 storage beneath a fitted motherboard heatsink in an open workstation service bay.

Performance beyond the short burst

Short transfers and extended writing place different demands on an SSD. Controller design, available space and write-cache behaviour affect sustained operation. Onboard DRAM and NAND-based write caching have different roles and should not be treated as the same feature.

Onboard DRAMSeparate volatile package on this illustrative board.
NAND-based write cachingAn operating mode within NAND on applicable designs, not necessarily another chip.

Different functions, product-specific implementation.

Illustrative power-loss protection components on an SSD.Hold-up capacitors

Protection for data in flight

On drives with hardware power-loss protection, stored energy supports specified internal tasks after input power is interrupted. The protection applies to the drive’s documented design. It is not a backup for the computer and does not replace a data-backup strategy.

  1. Input power lost
  2. Hold-up energy
  3. Defined internal writes completed

The protection scope follows the specific drive; system backup remains separate.

Illustrative SSD cooling arrangement.

Cooling that suits the drive

Thermal conditions influence sustained SSD operation. A compatible thermal pad, heatsink, enclosure or airflow arrangement helps the selected drive operate within its requirements. The cooling approach must fit the drive and its installed position.

Thermal interfaceHeat spreaderInstalled airflow
Conceptual storage data paths with and without an extra host-memory copy.

A more direct path to GPU memory

Compatible systems can use technologies such as NVIDIA GPUDirect Storage to avoid an extra copy through host memory. This is a system-and-software capability, not an automatic property of an NVMe SSD. Its benefit depends on a supported application and data path.

Conventional staging exampleSSD → host memory → GPU memory
Supported direct-storage pathSSD → GPU memory, avoiding an extra host-memory copy

Compatible platform, software and application required. Storage, host memory and GPU memory remain distinct.

Technical reading

Linked examples explain storage concepts; they are not Cloud 9 products.

STORAGE AT WORK

Where storage changes the working experience.

The storage requirement changes through the AI workflow. Select for the data that needs to be accessed, the writes that must be sustained and the capacity the work needs to retain.

Illustrative dataset preparation workflow with solid-state working storage.
Source dataPrepared batchesTraining input

Training and dataset preparation

Assemble, transform and revisit the data used by a model. Fast access matters when data loading limits progress, particularly with substantial image, audio or video datasets. Preprocessing, caching and file organisation remain part of the same pipeline.

Illustrative saved experiment states and checkpoint storage.
Save stateRetain versionsResume work

Saving progress and returning to an experiment

Checkpoints preserve the state of a run so work can resume or be compared. Storage needs to accommodate the retained versions and the write pattern involved. Consider sustained writes and endurance alongside the capacity needed for the experiment.

Conceptual model-loading and document-retrieval tasks supported by storage.
Load or change a modelRetrieve working documentsResident compute has different limits

Model loading, retrieval and inference services

Storage contributes when models are loaded or changed, and when an application accesses disk-backed documents or other working data. Once a model and its active data are resident in memory, a faster SSD does not automatically increase token-generation speed.

Illustrative production media and intermediate files stored for an AI-assisted creative workflow.
Source mediaWorking cacheVariationsSaved output

Generative media and production content

Source media, working caches, intermediate files and saved outputs form a substantial part of a production environment. Responsive working storage and sufficient local capacity keep those materials accessible around the compute-intensive stages of creation.

Flash storage avoids mechanical seek delays during active data access. Choose storage around the application’s data flow, with separate provision for cold archives and backup.

THE COMPLETE SYSTEM

Storage selected around the complete system.

The right SSD needs to fit the platform as well as the workload. Connections, drive bays, cooling, capacity and write requirements all influence the storage configuration.

Cloud 9 sources and supplies SSDs as individual components and as part of complete AI workstations and server systems. The specification follows the intended application, the data it uses and the environment in which it operates.

SSDs shown in the context of a complete AI computing system.
Persistent storageHost working memoryAccelerated compute
Functional system illustration. SSD storage, host memory and GPU memory have different roles and do not form one automatic capacity pool.

Exploring: M.2 2280 / Onboard-DRAM example (illustrative example)

Fit and connection

Confirm the supported interface, physical format, slot or bay and any shared host resources.

Capacity and writes

Allow for the active library, working files, checkpoints, retention and the expected write pattern.

Operation and protection

Match cooling and power-loss requirements to the actual drive; plan backup independently.